Mô đun cáp quang MelsecNet/10 Mitsubishi A1SJ71QLP21

A1SJ71QLP21. Fiber-Optic cable Data link. Truyền thông mạng MelsecNet/10 bằng cáp quang. Sử dụng với Q2ASCPU, Q2ASHCPU. Xuất xứ: Japan. Used, mới 85%, nguyên zin
Nhà sản xuất: Mitsubishi - Japan
A1SJ71QLP21 - Bảo hành 6 tháng
Giá cũ: 3.000.000 (VND)
Giá: 2.500.000 (VND)
Liên hệ để biết thêm chi tiết
  -  
a.Thịnh
  -  

Đặc tính kỹ thuật:

Mã hàng: A1SJ71QLP21

Fiber-Optic cable Data link 

Application: the control station, normal station and remote master station of MELSECNET/10

Max link points per network:

  • X/Y: 8192 points
  • B: 8192 points
  • W: 8192 points

Max link points per station:

  • PLC to PLC network: < 2000 bytes
  • Remote I/O network:
    • remote master station -> remote I/O station: < 1600 bytes
    • remote I/O station -> remote master station: < 1600 bytes
    • remote master station <-> remote sub master station: < 2000 bytes

Chế độ hoạt động - mode: MELSECNET/10

Tốc độ truyền thông: 10 Mbps (20 Mbps to multiple transmission)

Phương pháp truyền: Token ring

Phương pháp đồng bộ: Frame synchronous

Transmission circuit format: double loop

General extention distance: 30 km (tham khảo tài liệu)

Station to station distance: 300m ~ 1km

Số network kết nối: 239 (the sum total of PLC to PLC network and remote I/O network)

Số groups: 9 (only for PLC to PLC network)

Số station/network:

  • PLC to PLC network: 64 stations (control station: 1; normal stations: 63)
  • Remote I/O network: 65 stations (remote master station: 1; remote i/o staions: 64)

Số mô đun lắp trên 1 CPU Q2ASCPU(S1), Q2ASHCPU(S1): 4

Coding method: NRZI signal (Non return to zero Inverted)

Transmission format: conform to HDLC (frame format)

Error control method: retry by CRC

RAS function:

  • Loopback function on error detection or cable disconnection
  • Diagnostic function for local link circuit check
  • Prevention of system down due to shifting to control station (only for PLC to PLC network)
  • Abnormality detection by link special relay and registor
  • Network monitor, each type of diagnostic function
  • Transient transmission possible even when there is PC CPU abnormality

Transient transmission: N:N intercommunication (monitor, program ubload/download, etc)

Nguồn nội tiêu thụ: 5VDC 0.65A

Đấu dây: 2-core optical connector plug

Mở rộng cổng truyền thông cáp quang mạng Melsecnet/10 "plc to plc"/"remote io" cho PLC Mitsubishi: Q2ASCPU, Q2ASCPU-S1, Q2ASHCPU, Q2ASHCPU-S1

==========================

Tài liệu: 

A1SJ71QLP21(S)_BR11_hardware

QnA_Q4AR_MelsecNet10_reference